Olympus FE-100 vs. Nikon Coolpix L24

Comparison

change cameras »
FE-100 image
vs
Coolpix L24 image
Olympus FE-100 Nikon Coolpix L24
check price » check price »
Megapixels
4.00
14.10
Max. image resolution
2272 x 1704
4320 x 3240

Sensor

Sensor type
CCD
CCD
Sensor size
1/2.5" (~ 5.75 x 4.32 mm)
1/2.3" (~ 6.16 x 4.62 mm)
Sensor resolution
2306 x 1734
4330 x 3256
Diagonal
7.19 mm
7.70 mm
Sensor size comparison
Sensor size is generally a good indicator of the quality of the camera. Sensors can vary greatly in size. As a general rule, the bigger the sensor, the better the image quality.

Bigger sensors are more effective because they have more surface area to capture light. An important factor when comparing digital cameras is also camera generation. Generally, newer sensors will outperform the older.

Learn more about sensor sizes »

Actual sensor size

Note: Actual size is set to screen → change »
vs
1 : 1.15
(ratio)
Olympus FE-100 Nikon Coolpix L24
Surface area:
24.84 mm² vs 28.46 mm²
Difference: 3.62 mm² (15%)
L24 sensor is approx. 1.15x bigger than FE-100 sensor.
Note: You are comparing sensors of very different generations. There is a gap of 6 years between Olympus FE-100 (2005) and Nikon L24 (2011). Six years is a lot of time in terms of technology, meaning newer sensors are overall much more efficient than the older ones.
Pixel pitch
2.49 µm
1.42 µm
Pixel pitch tells you the distance from the center of one pixel (photosite) to the center of the next. It tells you how close the pixels are to each other.

The bigger the pixel pitch, the further apart they are and the bigger each pixel is. Bigger pixels tend to have better signal to noise ratio and greater dynamic range.
Difference: 1.07 µm (75%)
Pixel pitch of FE-100 is approx. 75% higher than pixel pitch of L24.
Pixel area
6.2 µm²
2.02 µm²
Pixel or photosite area affects how much light per pixel can be gathered. The larger it is the more light can be collected by a single pixel.

Larger pixels have the potential to collect more photons, resulting in greater dynamic range, while smaller pixels provide higher resolutions (more detail) for a given sensor size.
Relative pixel sizes:
vs
Pixel area difference: 4.18 µm² (207%)
A pixel on Olympus FE-100 sensor is approx. 207% bigger than a pixel on Nikon L24.
Pixel density
16.08 MP/cm²
49.41 MP/cm²
Pixel density tells you how many million pixels fit or would fit in one square cm of the sensor.

Higher pixel density means smaller pixels and lower pixel density means larger pixels.
Difference: 33.33 µm (207%)
Nikon L24 has approx. 207% higher pixel density than Olympus FE-100.
To learn about the accuracy of these numbers, click here.



Specs

Olympus FE-100
Nikon L24
Crop factor
6.02
5.62
Total megapixels
4.20
14.50
Effective megapixels
4.00
14.10
Optical zoom
3x
3.6x
Digital zoom
Yes
Yes
ISO sensitivity
Auto, (64 - 320)
Auto, 80, 100 200, 400, 800, 1600, 3200, 6400
RAW
Manual focus
Normal focus range
50 cm
30 cm
Macro focus range
2 cm
5 cm
Focal length (35mm equiv.)
35 - 106 mm
37 - 134 mm
Aperture priority
No
No
Max. aperture
f3 - f5
f3.1 - f6.7
Max. aperture (35mm equiv.)
f18.1 - f30.1
f17.4 - f37.7
Metering
Multi, Center-weighted, Spot
Multi, Average
Exposure compensation
±2 EV (in 1/3 EV steps)
±2 EV (in 1/3 EV steps)
Shutter priority
No
No
Min. shutter speed
2 sec
4 sec
Max. shutter speed
1/2000 sec
1/4000 sec
Built-in flash
External flash
Viewfinder
None
None
White balance presets
5
5
Screen size
1.5"
3"
Screen resolution
130,000 dots
230,000 dots
Video capture
Max. video resolution
Storage types
xD Picture card
SD / SDHC/SDXC
USB
USB 1.0
USB 2.0 (480 Mbit/sec)
HDMI
Wireless
GPS
Battery
AA (2) batteries (NiMH recommended)
2 x AA batteries
Weight
160 g
182 g
Dimensions
88 x 63 x 39 mm
98 x 61 x 28 mm
Year
2005
2011




Choose cameras to compare

vs

Diagonal

Diagonal is calculated by the use of Pythagorean theorem:
Diagonal =  w² + h²
where w = sensor width and h = sensor height

Olympus FE-100 diagonal

The diagonal of FE-100 sensor is not 1/2.5 or 0.4" (10.2 mm) as you might expect, but approximately two thirds of that value - 7.19 mm. If you want to know why, see sensor sizes.

w = 5.75 mm
h = 4.32 mm
Diagonal =  5.75² + 4.32²   = 7.19 mm

Nikon L24 diagonal

The diagonal of L24 sensor is not 1/2.3 or 0.43" (11 mm) as you might expect, but approximately two thirds of that value - 7.7 mm. If you want to know why, see sensor sizes.

w = 6.16 mm
h = 4.62 mm
Diagonal =  6.16² + 4.62²   = 7.70 mm


Surface area

Surface area is calculated by multiplying the width and the height of a sensor.

FE-100 sensor area

Width = 5.75 mm
Height = 4.32 mm

Surface area = 5.75 × 4.32 = 24.84 mm²

L24 sensor area

Width = 6.16 mm
Height = 4.62 mm

Surface area = 6.16 × 4.62 = 28.46 mm²


Pixel pitch

Pixel pitch is the distance from the center of one pixel to the center of the next measured in micrometers (µm). It can be calculated with the following formula:
Pixel pitch =   sensor width in mm  × 1000
sensor resolution width in pixels

FE-100 pixel pitch

Sensor width = 5.75 mm
Sensor resolution width = 2306 pixels
Pixel pitch =   5.75  × 1000  = 2.49 µm
2306

L24 pixel pitch

Sensor width = 6.16 mm
Sensor resolution width = 4330 pixels
Pixel pitch =   6.16  × 1000  = 1.42 µm
4330


Pixel area

The area of one pixel can be calculated by simply squaring the pixel pitch:
Pixel area = pixel pitch²

You could also divide sensor surface area with effective megapixels:
Pixel area =   sensor surface area in mm²
effective megapixels

FE-100 pixel area

Pixel pitch = 2.49 µm

Pixel area = 2.49² = 6.2 µm²

L24 pixel area

Pixel pitch = 1.42 µm

Pixel area = 1.42² = 2.02 µm²


Pixel density

Pixel density can be calculated with the following formula:
Pixel density =  ( sensor resolution width in pixels )² / 1000000
sensor width in cm

One could also use this formula:
Pixel density =   effective megapixels × 1000000  / 10000
sensor surface area in mm²

FE-100 pixel density

Sensor resolution width = 2306 pixels
Sensor width = 0.575 cm

Pixel density = (2306 / 0.575)² / 1000000 = 16.08 MP/cm²

L24 pixel density

Sensor resolution width = 4330 pixels
Sensor width = 0.616 cm

Pixel density = (4330 / 0.616)² / 1000000 = 49.41 MP/cm²


Sensor resolution

Sensor resolution is calculated from sensor size and effective megapixels. It's slightly higher than maximum (not interpolated) image resolution which is usually stated on camera specifications. Sensor resolution is used in pixel pitch, pixel area, and pixel density formula. For sake of simplicity, we're going to calculate it in 3 stages.

1. First we need to find the ratio between horizontal and vertical length by dividing the former with the latter (aspect ratio). It's usually 1.33 (4:3) or 1.5 (3:2), but not always.

2. With the ratio (r) known we can calculate the X from the formula below, where X is a vertical number of pixels:
(X × r) × X = effective megapixels × 1000000    →   
X =  effective megapixels × 1000000
r
3. To get sensor resolution we then multiply X with the corresponding ratio:

Resolution horizontal: X × r
Resolution vertical: X

FE-100 sensor resolution

Sensor width = 5.75 mm
Sensor height = 4.32 mm
Effective megapixels = 4.00
r = 5.75/4.32 = 1.33
X =  4.00 × 1000000  = 1734
1.33
Resolution horizontal: X × r = 1734 × 1.33 = 2306
Resolution vertical: X = 1734

Sensor resolution = 2306 x 1734

L24 sensor resolution

Sensor width = 6.16 mm
Sensor height = 4.62 mm
Effective megapixels = 14.10
r = 6.16/4.62 = 1.33
X =  14.10 × 1000000  = 3256
1.33
Resolution horizontal: X × r = 3256 × 1.33 = 4330
Resolution vertical: X = 3256

Sensor resolution = 4330 x 3256


Crop factor

Crop factor or focal length multiplier is calculated by dividing the diagonal of 35 mm film (43.27 mm) with the diagonal of the sensor.
Crop factor =   43.27 mm
sensor diagonal in mm


FE-100 crop factor

Sensor diagonal in mm = 7.19 mm
Crop factor =   43.27  = 6.02
7.19

L24 crop factor

Sensor diagonal in mm = 7.70 mm
Crop factor =   43.27  = 5.62
7.70

35 mm equivalent aperture

Equivalent aperture (in 135 film terms) is calculated by multiplying lens aperture with crop factor (a.k.a. focal length multiplier).

FE-100 equivalent aperture

Crop factor = 6.02
Aperture = f3 - f5

35-mm equivalent aperture = (f3 - f5) × 6.02 = f18.1 - f30.1

L24 equivalent aperture

Crop factor = 5.62
Aperture = f3.1 - f6.7

35-mm equivalent aperture = (f3.1 - f6.7) × 5.62 = f17.4 - f37.7

Enter your screen size (diagonal)

My screen size is  inches



Actual size is currently adjusted to screen.

If your screen (phone, tablet, or monitor) is not in diagonal, then the actual size of a sensor won't be shown correctly.